← Spill Compliance Resource Center

A puddle of oil or coolant is a slip waiting to happen. OSHA’s general industry rules require floors kept clean and, as far as feasible, dry. Hazardous waste cleanup sites covered by OSHA’s HAZWOPER standard must also keep absorbents and salvage drums on hand. Here is what the rules say.

The short version

  • All walking-working surfaces must be kept clean, orderly and sanitary, and free of hazards such as leaks and spills (29 CFR 1910.22(a)).
  • Workroom floors must be kept clean and, to the extent feasible, dry. Where wet processes are used, keep drainage working and provide dry standing places such as platforms or mats where feasible.
  • Inspect surfaces regularly, and fix or guard a hazard before anyone uses the surface again.
  • At hazardous waste cleanup sites covered by HAZWOPER, DOT salvage drums and suitable absorbent must be kept available where spills, leaks or ruptures may occur.
  • Outdoor flammable liquid container storage must be graded to divert spills, or surrounded by a curb at least 6 inches high.

Floors and walkways: 1910.22

OSHA’s walking-working surfaces rule, 29 CFR 1910.22, applies to almost every general industry workplace. It requires the employer to make sure:

  • All places of employment, passageways, storerooms and service rooms are kept clean, orderly and sanitary.
  • Workroom floors are kept clean and, to the extent feasible, dry. Where wet processes are used, drainage is maintained and, to the extent feasible, dry standing places such as false floors, platforms and mats are provided.
  • Walking-working surfaces are kept free of hazards such as sharp objects, corrosion, leaks, spills, snow and ice.
  • Surfaces are inspected regularly, and hazards are corrected before employees use the surface again. If a fix can’t be made right away, the hazard must be guarded until it is.

In practice, that means two things: stop the leak, and control what drips in the meantime. Absorbent mats and pads under machines, fluid dispensers and work stations keep the floor dry between repairs, and they make the problem easy to spot.

Small spills vs. emergency response

OSHA draws a line between everyday spills and emergencies. Under the HAZWOPER definitions in 29 CFR 1910.120(a)(3), a release that can be absorbed, neutralized or otherwise controlled at the time of release by employees in the immediate area, or by maintenance personnel, is an incidental release, not an emergency response.

That is why a spill kit within reach matters: the people who are already there can handle a small spill safely and quickly. Larger or uncontrolled releases, handled by responders from outside the area, fall under HAZWOPER’s emergency response training and planning rules. Workers who clean up incidental spills still need hazard communication training on the chemicals involved.

HAZWOPER sites: absorbents and salvage drums

HAZWOPER covers cleanups at uncontrolled hazardous waste sites, RCRA corrective actions, treatment, storage and disposal facilities, and emergency response operations. For cleanup operations (paragraphs (a)(1)(i) through (iii)), the drum and container handling rules in 1910.120(j)(1) say:

  • (vii) U.S. Department of Transportation specified salvage drums or containers and suitable quantities of proper absorbent must be kept available and used in areas where spills, leaks or ruptures may occur.
  • (viii) Where major spills may occur, a spill containment program must be in place to contain and isolate the entire volume of the hazardous substance being transferred.

A DOT salvage drum has to be a removable-head UN 1A2, 1B2, 1N2 or 1H2 drum tested and marked for Packing Group III or higher (49 CFR 173.3(c)). Not every drum that a spill kit ships in is UN-rated, so check the marking if you plan to use the drum that way.

Flammable liquid storage

For flammable liquid containers stored outside buildings, 29 CFR 1910.106(d)(6)(iii) requires the storage area to be graded so spills are diverted away from buildings, or surrounded by a curb at least 6 inches high, with a way to drain rainwater and spills to a safe location. Spill pallets and berms are a common way to contain drums and totes in these areas.

Laboratories

Labs covered by 29 CFR 1910.1450 need a written Chemical Hygiene Plan. OSHA’s non-mandatory Appendix A lists “emergency procedures for accidents and spills” among the topics a good plan covers, and any employee involved in a spill that could cause a hazardous exposure must be offered a medical consultation. Small hazmat or universal spill kits sized for bench-top spills are the usual tool.

Products that help

Spill and floor safety checklist

  • Walk the floor regularly and note leaks, drips and wet areas.
  • Fix leaks at the source; use absorbent mats or pads to control drips until the repair is done.
  • Keep a spill kit within reach of every area where liquids are used, and restock it after each use.
  • Train employees to handle incidental spills, including the hazards of the chemicals involved.
  • Contain outdoor flammable liquid storage, and keep drains free.
  • At HAZWOPER cleanup sites, keep UN-rated salvage drums and enough absorbent where spills may occur.

Not sure what fits your site? Call (800) 869-9633, Mon–Fri 9–5 PT, or email [email protected]. Tell us what you store and where, and we’ll help you size it.

Last reviewed November 2026 against the current Code of Federal Regulations (eCFR). This is a plain-English summary, not legal advice. State rules, local fire codes and your own plan or permit can be stricter, so check the regulation text and your permit before you rely on it.